HANG ZHOU TAI LIAN CRYOGENIC EQUIPMENT CO., LTD.
|
Gold Index: 5724
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
99.6% Air Separation Plant KDON-1400Y/2000 Liquid Industrial Oxygen Plant With Low Energy
Consumption
1. lant design basis (It needs buyer’s confirmation)
Design point of Atmosphere |
|
Ø Atmosphere pressure |
101.3kPa(A) |
Ø Atmosphere tempt. |
30 |
Ø Relative humidity |
75% |
Ø O2 contained in air |
20.95% O2 |
Atmosphere tempt. |
|
Ø Annual average temp. |
18.4 |
Ø Max. Tempt. |
40 |
Ø Min. Tempt. |
-1.8 |
Ø Summer average temp. |
30 |
Ø Winter average temp. |
7.5 |
Earth shake degree |
6degree |
Altitude: |
50m |
Impurity in air |
|
Ø CO2 |
≤350 ppm |
Ø SO2 |
≤0.44 mg/m3 |
Ø H2S |
≤2.3 mg/ m3 |
Ø CH4 |
≤5.2mg/ m3 |
Ø C2H2 |
≤0.03 ppm |
Ø CnHm(except C2H2) |
≤5 ppm |
Ø Dust content |
≤10mg/m3 |
Recycling water |
|
Ø Inlet temp. |
30 |
Ø Inlet pressure |
0.4 MPa(G) |
Ø Maximum pressure drop |
0.2 MPa(G) |
Ø Maximum temperature rise |
10 |
Ø Cooling water turbidity |
12 mg/L |
Ø PH value |
7.2 |
Ø General hardness |
2.5 |
Ø Fouling factor |
0.0004 m2 hºC/ K.W |
Power condition |
|
Ø High voltage power |
10,000V±5% three phases three wires |
Ø Low voltage power |
380V/220V±5% AC three phases four wires |
Ø Frequency |
50±0.5HZ |
Instrument gas ( used for starting) |
|
Ø Pressure |
0.5 MPa(G) |
Ø Temp. |
≤30 |
Ø Dew point |
-40 |
Ø Flow |
300m3/h |
Ø Requirement |
Oil freeFlow |
2. Main parameter
Capacity and purity(outlet cold box): |
|||
Design condition |
|||
Media |
capacity(Nm3/h) |
purity |
pressure(MpaG) |
LO2 |
1400 |
≥99.6% O2 |
0.16 |
N2 |
2000 |
≤3 ppm O2 |
0.012 |
Design condition |
|||
LO2 |
1000 |
≥99.6% O2 |
0.16 |
O2 |
400 |
≥99.6% O2 |
0.034 |
LN2 |
400 |
≤3 ppm O2 |
0.2 |
Note:Nm/h means under the condition of 0 and 760mmHg, Liquid production converts to gas capacity Pressure is calculated as 0 m altitude from the exit of cold box |
Running period between 2 defrosting times |
>2 years |
Defrosting time |
36 hours |
Starting time |
16 hours |
Power consumption table |
||||||
No. |
Equipment |
Motor power(fixed power)kW |
Normal working condition Shaft power kW |
Voltage degree |
Notice |
|
1. |
Raw air compressor |
2235 |
2114 |
10KV |
Samsung |
|
2. |
Air pre-cooling system |
|||||
Cooling water pump motor |
15 |
10 |
380/220V |
One in use one standby |
||
Condensing water pump motor |
11 |
6 |
380/220V |
One in use one standby |
||
Water chiller |
35 |
25 |
380/220V |
Spares |
||
3. |
Cryogenic chiller |
60 |
54 |
380/220V |
|
|
4. |
MS purification system |
|||||
Heater |
210 |
Average:80 |
380/220V |
Switching operation |
||
5. |
Expander oil pump |
3 |
2 |
380/220V |
One in use one standby |
|
6. |
Liquid storage system |
|||||
LO2 transportation pump |
15 |
10 |
380/220V |
Intermittent operation |
||
LN2 transportation pump |
15 |
10 |
380/220V |
Intermittent operation |
||
7. |
Instrument system |
|
average:10 |
380/220V |