1.1 Design basic conditions
Atmosphere pressure 0.1013Mpa (A)
Atmosphere tempt. 30
Relative humidity 80%
O2 contained in air 20.95% O2
1.2 Cooling water
Feeding water:Tempt. 30)
Pressure 0.45MPa(G)
PH value 78
Fouling factor 0.0004m2 .h/Kcal
Total hardness 100mg/L
Turbidity 1030mg/L
1.3 Earth quake: 6 degree
1.4 Sea level: 50m
1.5 Impurity in atmosphere
CO2 ≤350 ppm
SO2 ≤0.44 mg/m3
H2S ≤2.3 mg/m3
CH4 ≤5.2mg/m3
C2H2 ≤0.03 ppm
CnHm(excluding C2H2) ≤5 ppm
Dust content ≤10mg/m3
1.5 Power supply
Low voltage 380V/220V±5%
AC,3-phase,4-wire
Frequency 50±0.5Hz
Loaded power 220KW(Name plate power, not incl. O2 compressor)
2. Main technical performance parameters
2.1 Product output,purity , pressure
O2 output 250m3/h±5%
O2 purity ≥99.6%O2
O2 pressure 0.034MPa(G)
N2 output 500m3/h±5%
N2 purity ≤10ppmO2
N2 pressure 0.012 MPa(G)
Product quantity status(at 0,101.325Kpa)
2.2 Start pressure 0.65MPa(G)
2.3 Plant operation period(between two defrosting times) 12 months
2.4 Start time 24 hours
2.5 Specific power 0.65kWh/m3O2(not incl.
O2 compressor)
3.Pocess description:
KDON-250/500 air separation plant is of low pressure process.
Raw air comes from air, goes through air filter for removal of dust and other mechanical particle and enters non-lub air compressor to be compressed by two stage compressor to approx. 0.65MPa(g).It goes through cooler and enters precooling unit to be cooled to 510. Then it goes to switch-over MS purifier for removal of moisture, CO2, carbon hydrogen. Purifier consists of two molecular sieve filled vessels. One is in use while anther is under regeneration by waste nitrogen from the cold box and through heater heating.
After purified, small part of it is used as bearing gas for turbine expander, other enters cold box to be cooled by reflux(pure oxygen, pure nitrogen and waste nitrogen) in main heat exchanger. Part of air is abstracted from the middle part of main heat exchanger and goes to expansion turbine for production of cold. Most of expanded air goes through subcooler which is cooled by oxygen from upper column to be delivered to upper column. Small part of it goes through bypass to waste nitrogen pipe directly and is reheated to go out of the cold box. The other part of air continues to be cooled to near liquid air tempt to lower column.
In lower column